Difference between revisions of "Analysis Command"

From OSUPDOCS
Jump to navigation Jump to search
Line 22: Line 22:
== Notes ==
== Notes ==


* The first three (0,1,2) are for [[FEA Input Files|FEA calculations only]], while the rest (10,11,12,13) or for [[MPM Input Filess|MPM calculations only]].
* The first three (0,1,2) are for [[FEA Input Files|FEA calculations only]], while the rest (10,11,12,13) or for [[MPM Input Files|MPM calculations only]].


* In axisymmetric analyses, the x, y, z, directions become R, Z, and &theta; directions. If any commands do not mention use of R and Z, they may still work or you can use x and y to mean the same thing. When visualizing results, most labels are changed to reflect R, Z, and &theta; coordinates. The implementation of axisymmetric MPM is described in a paper by Nairn and Guilkey.<ref>J.A. Nairn and J.E. Guilkey, "Axisymmetric Form of the Generalized Interpolation Material Point Method,"> <i>Computer Methods in Applied Mechanics and Engineering</i>, submitted (2013) ([http://www.cof.orst.edu/cof/wse/faculty/Nairn/papers/AxisymGIMP.pdf See PDF]).</ref>
* In axisymmetric analyses, the x, y, z, directions become R, Z, and &theta; directions. If any commands do not mention use of R and Z, they may still work or you can use x and y to mean the same thing. When visualizing results, most labels are changed to reflect R, Z, and &theta; coordinates. The implementation of axisymmetric MPM is described in a paper by Nairn and Guilkey.<ref>J.A. Nairn and J.E. Guilkey, "Axisymmetric Form of the Generalized Interpolation Material Point Method,"> <i>Computer Methods in Applied Mechanics and Engineering</i>, submitted (2013) ([http://www.cof.orst.edu/cof/wse/faculty/Nairn/papers/AxisymGIMP.pdf See PDF]).</ref>

Revision as of 09:08, 25 May 2013

Both MPM and FEA calculations can do 2D or axisymmetric calculations. MPM can additionally do 3D calculations. You pick the type of analysis to run with an analysis command. In command scripts, the format is

Analysis (name or number)

In XML files it is

<Analysis>number<Analysis>

Analysis Options

The possible analysis types, by number or name to use in above commands, are:

  • 0 = "Plane Strain" for a 2D plane strain FEA analysis
  • 1 = "Plane stress" for a 2D plane stress FEA analysis
  • 2 = "Axisymmetric" for an Axisymmetric FEA analysis
  • 10 = "Plane Strain MPM" for 2D plane strain dynamic MPM analysis
  • 11 = "Plane Stress MPM" or 2D plane stress dynamic MPM analysis
  • 12 = "3D MPM" or 3D dynamic MPM analysis
  • 13 = "Axisymmetric MPM" for axisymmetric dynamic MPM analysis


Notes

  • In axisymmetric analyses, the x, y, z, directions become R, Z, and θ directions. If any commands do not mention use of R and Z, they may still work or you can use x and y to mean the same thing. When visualizing results, most labels are changed to reflect R, Z, and θ coordinates. The implementation of axisymmetric MPM is described in a paper by Nairn and Guilkey.[1]

References

  1. J.A. Nairn and J.E. Guilkey, "Axisymmetric Form of the Generalized Interpolation Material Point Method,"> Computer Methods in Applied Mechanics and Engineering, submitted (2013) (See PDF).