Linear Softening
The Softening Law
A linear softening law has the following values:
[math]\displaystyle{ f(\delta,s) = 1 - {\delta\over \delta_{max} } = 1 - {\delta\over 2sG_c} }[/math]
which follows from
[math]\displaystyle{ sG_c = \int_0^{\delta_{max}} f(\delta,s) = {\delta_{max}\over 2} \quad{\rm or}\quad \delta_{max} = 2sG_c }[/math]
where s is the softening scaling term and Gc is toughness of the law (and the law's only property). The critical cracking strain, [math]\displaystyle{ \delta_{max} }[/math], which depends on mesh size and crack orientation, is calculated above and is not a law property to be provided.
The area (or energy dissipation term) is
[math]\displaystyle{ A(\delta,s) = {\delta\over 2} }[/math]
The stability condition is:
[math]\displaystyle{ \max\bigl(-f'(\delta,s)\bigr) = {1\over \delta_{max}} = {1\over 2sG_c} }[/math]
Softening Law Properties
Only one property is needed to define a linear softening law:
Property | Description | Units | Default |
---|---|---|---|
Gc | The toughness associated with the this softening law | energy release units | none |