Difference between revisions of "LoadControl Custom Task"

From OSUPDOCS
Jump to navigation Jump to search
Line 3: Line 3:
== Introduction ==
== Introduction ==


This CustomTask tries to achieve the load requested from a provided [[User Defined Functions|user defined function]] by adjusting the velocity of a block of rigid material points. It does that by dynamically estimating the relationship between the displacement and load and then uses a PID control algorithm<ref>J. C. Simo, "Framework for finite elastoplasticity. Part I", ''Computer Methods in Applied Mechanics and Engineering'', '''66''', 199-219 (1988).</ref> to adjust the velocity.
This CustomTask tries to achieve the load requested from a provided [[User Defined Functions|user defined function]] by adjusting the velocity of a block of rigid material points. It does that by dynamically estimating the relationship between the displacement and load and then uses a PID control algorithm<ref>[https://en.wikipedia.org/wiki/PID_controller Wikepedia.com, "PID Controller"]</ref> to adjust the velocity.


A <tt>LoadControl</tt> custom task needs either [[MPM Global Archiving Options|global contact]] or [[MPM Global Archiving Options|global reaction]] for the specified [[Rigid Material|Rigid material]] depending on if contact for that material is enabled. This task will not work if rigid materials have a velocity function assigned, because these functions over-ride the load control velocity.
A <tt>LoadControl</tt> custom task needs either [[MPM Global Archiving Options|global contact]] or [[MPM Global Archiving Options|global reaction]] for the specified [[Rigid Material|Rigid material]] depending on if contact for that material is enabled. This task will not work if rigid materials have a velocity function assigned, because these functions over-ride the load control velocity.

Revision as of 17:58, 27 July 2017

A custom task run a load control simulation based on calculations contact or reaction forces. .

Introduction

This CustomTask tries to achieve the load requested from a provided user defined function by adjusting the velocity of a block of rigid material points. It does that by dynamically estimating the relationship between the displacement and load and then uses a PID control algorithm[1] to adjust the velocity.

A LoadControl custom task needs either global contact or global reaction for the specified Rigid material depending on if contact for that material is enabled. This task will not work if rigid materials have a velocity function assigned, because these functions over-ride the load control velocity.

Theory

This custom task tries to dynamically estimate the relationship between load and displacement of the rigid material using the following equation:

      [math]\displaystyle{ A_t = \text{arg}\min_{A} \left[ (1-\alpha) \frac{(L-Ax)^2}{0.5(L^2+(A_{t-1}x)^2)}+\alpha\frac{(A-A_{t-1})^2}{A_{t-1}^2}\right] }[/math]

where [math]\displaystyle{ A_t }[/math] is the estimate the relationship between load and displacement (or the stiffness) at time t, x is the displacement, L is the recorded load and [math]\displaystyle{ \alpha }[/math] is the smooth parameter. The minimization problem has the analytical solution:

      [math]\displaystyle{ A_t =\frac{\lambda L x + \gamma A_{t-1}}{\lambda x^2 +\gamma} }[/math]   where   [math]\displaystyle{ \lambda =\frac{2(1-\alpha)}{L^2+(A_{t-1}x)^2} }[/math]   and   [math]\displaystyle{ \gamma =\frac{\alpha}{A_{t-1}^2} }[/math].

Then the error between requested load L(t) and recorded load L is smoothed and converted to velocity as:

      [math]\displaystyle{ e_t =(1-\alpha)\frac{L(t)-L}{A_t}+\alpha e_{t-1} }[/math]

The integrated error is calculated as:

      [math]\displaystyle{ Ie_t =\frac{L(t)-L}{A_t}+ Ie_{t-1} }[/math]

The derivative error is calculated with Brown's double exponential smoothing as:

      [math]\displaystyle{ e{\scriptstyle 2}_t =(1-\alpha)e_t+ \alpha e{\scriptstyle 2}_{t-1} }[/math]

and

      [math]\displaystyle{ De_t = \frac{1-\alpha}{\alpha}(e_t-e{\scriptstyle 2}_t) }[/math]

then finally the velocity is set using the PID algorithm:

      [math]\displaystyle{ V_t = K_p e_t + K_i Ie_t + 0.25K_i De_t }[/math]

Note: If the velocity has a magnitude larger than MaxVelocity than it is given that magnitude and the integrated error for that time step is not accrued.

Task Scheduling

In scripted files, a LoadControl custom task is scheduled with the following block:

CustomTask LoadControl
Parameter velocity,(number)
Parameter material,(int)
Parameter direction,(int)
Parameter MaxVelocity,(number)
Parameter "Load_Function (function)"
Parameter Kp,(number)
Parameter Ki,(number)
Parameter smooth,(number)
Parameter UpdateTime,(number)

In XML files, these task options are scheduled using <Schedule> elements, which must be within the single <CustomTasks> block:

<Schedule name='LoadControl'>
   <Parameter name='velocity'>(number)</Parameter>
   <Parameter name='material'>(int)</Parameter>
   <Parameter name='direction'>(int)</Parameter>
   <Parameter name='MaxVelocity'>(number)</Parameter>
   <Parameter name='Load_Function (function)'/>
   <Parameter name='Kp'>(number)</Parameter>
   <Parameter name='Ki'>(number)</Parameter>
   <Parameter name='smooth'>(number)</Parameter>
   <Parameter name='UpdateTime'>(number)</Parameter>
</Schedule>


These are the parameters that this custom task needs to operate:

  • velocity - This is the starting velocity of the simulation for the specified Rigid material in velocity units. The sign of this parameter is probably more important than its value, as long as it is something reasonable. It is needed for initializing the load control.
  • material - The material number of the Rigid material to be controlled (must be entered by number).
  • direction - An integer (1, 2, or 3) to choose the direction (x, y, or z) to contrtol for velocity and load.
  • MaxVelocity - A positive number that limits the magnitude of the velocity of the controlled material (default is 1000 in velocity units).
  • Load_Function - A user defined function that gives the desired load (in force-time units). This task doesn't work well with discontinuous functions. Note that the function is provided in the name of the parameter as a single string. The first word of the string must be "Load_Function" and the remainder of the name is the user defined function.
  • smooth - Exponential smoothing parameter in the range (0,1). Controls how fast the dynamic relationship between distance and load is updated and also how much smoothing is done on the load values (default 0.95).
  • UpdateTime - The time interval between runs of the load control algorithm (in alt time units). Should be equal to or greater than the global archive time. To run control algorithm on every time step, set global archive time to zero and omit this parameter.

These following parameters are for the control algorithm. The provided default parameters don't seem to really work. Try increasing Kp until it overshoots the target, then increase Ki to lessen the overshoot.

  • Kp - Proportional gain factor for PID algorithm (default 0.1).
  • Ki - Integral and Derivative gain factors for PID algorithm. (Note: Kd = 0.25Ki) (default 0.001).

To be developed

Contact forces are corrupted with fat tail noise. A median filter would help reduce the effect of this noise.

Self-tuning parameters.

References