Difference between revisions of "Exponential Softening"

From OSUPDOCS
Jump to navigation Jump to search
Line 27: Line 27:
=== Minimum <math>f(\delta,s)</math> ===
=== Minimum <math>f(\delta,s)</math> ===


In this law, it is desirable to define and minimum value for <math>f(\delta,s)</math>. If we define the minimum value as ''c'', this choice effective defines a maximum cracking strain:
This law requires selection of minimum value for <math>f(\delta,s)</math> below which the material point is marked as failed. If we define the minimum value as ''c'', this choice effective defines a maximum cracking strain:


&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;
Line 37: Line 37:
<math>\delta_{max} = 4.60517 s G_c</math>
<math>\delta_{max} = 4.60517 s G_c</math>


Note that [[Linear Softening|linear softening]] has 2 in place of 4.60517 for finding maximum cracking strain.
Note that [[Linear Softening|linear softening]] has 2 in place of 4.60517 for finding maximum cracking strain. Without a minimum value, exponential softening would never fail. If you want to prevent failures, set the minimum value to a very small number (but it cannot be zero).


== Softening Law Properties ==
== Softening Law Properties ==

Revision as of 17:49, 13 November 2020

The Softening Law

A exponential softening law has the following form:

      [math]\displaystyle{ f(\delta,s) = e^{-k\delta} = e^{-\delta/(sG_c)} }[/math]

which follows from

      [math]\displaystyle{ sG_c = \int_0^{\delta_{max}} f(\delta,s) = {1\over k} \quad{\rm or}\quad k = {1\over sG_c} }[/math]

where s is the softening scaling term and Gc is toughness of the law (and the law's only property). The exponential decay rate, k, which depends on mesh size and crack orientation, is calculated above and is not a law property to be provided.

The area (or energy dissipation term) is

      [math]\displaystyle{ A(\delta,s) = sG_c - e^{-\delta/(sG_c)}\left(sG_c+{\delta\over2}\right) }[/math]

The stability condition is:

      [math]\displaystyle{ \max\bigl(-f'(\delta,s)\bigr) = k = {1\over sG_c} }[/math]

Minimum [math]\displaystyle{ f(\delta,s) }[/math]

This law requires selection of minimum value for [math]\displaystyle{ f(\delta,s) }[/math] below which the material point is marked as failed. If we define the minimum value as c, this choice effective defines a maximum cracking strain:

      [math]\displaystyle{ \delta_{max} = -{\ln c \over k} = -s G_c \ln c }[/math]

For example, picking c = 0.01 gives

      [math]\displaystyle{ \delta_{max} = 4.60517 s G_c }[/math]

Note that linear softening has 2 in place of 4.60517 for finding maximum cracking strain. Without a minimum value, exponential softening would never fail. If you want to prevent failures, set the minimum value to a very small number (but it cannot be zero).

Softening Law Properties

Only one property is needed to define an exponential softening law:

Property Description Units Default
Gc The toughness associated with the this softening law energy release units none
min Minimum [math]\displaystyle{ f(\delta,s) }[/math] or law is failed if gets below this value none 0.01